Hettich Rotolavit II

Centrifuge

The ROTOLAVIT II cell washing system simplifies routine tasks in transfusion center laboratories. It was developed for cross-matching, antibody screening, differentiation, and cell washing in TB tests. The modern touchscreen allows for easy and quick entry of up to 20 different programs. The centrifuge has a small footprint and provides reliable results at low consumable costs.

See all centrifuge products

Download the Rotolavit II brochure here:

pdf-brosjyrer-labhuset
Contact us
Frode Rangset

We would like to hear from you if you have any questions or inquiries about our services and products! Please get in touch, and we will assist you.

Frode Rangset
frode@labhuset.no
+47 94826016

Contact us

We would like to hear from you if you have any questions or inquiries about our services and products! Please get in touch, and we will assist you.

Frode Rangset

Frode Rangset
frode@labhuset.no
+47 94826016

rotolavit-II-sentrifuge
Hettich logo svart

Hettich Rotolavit II

Centrifuge

The ROTOLAVIT II cell washing system simplifies routine tasks in transfusion centre laboratories. It was developed for cross-matching, as well as antibody screening and differentiation, and for cell washing in TB tests. The modern touchscreen enables simple and rapid entry of up to 20 different programmes. The centrifuge has a small footprint and delivers reliable results at low consumable costs.

See all our Hettich centrifuges.

Download the Rotolavit II brochure here:

pdf-brosjyrer-labhuset
Send melding - Frode eng (#10)

Contact us

Frode Rangset

We would love to hear from you if you have any questions or enquiries about our services and products! Get in touch and we will be happy to help.

Frode Rangset

Send melding - Frode eng (#10)

Contact us

Frode Rangset

Frode Rangset

We would love to hear from you if you have any questions or enquiries about our services and products! Get in touch and we will be happy to help.

Product Specifications

Areas of Use

The ROTOLAVIT II is an automatic cell washing system developed specifically for serological analyses in transfusion centres and blood bank laboratories:

  • Cross-reaction testing (crossmatching) for blood type determination
  • Antibody screening and antibody differentiation
  • Cell washing in TB tests
  • Routine tasks in the daily laboratory work of transfusion centres
  • Serological testing in general

Advantages

  • Automatic cell washing — purpose-built for serological test procedures, significantly reducing manual workload
  • User-friendly touchscreen — intuitive colour touchscreen for rapid programme entry
  • 24 programme memories — flexible adaptation to different protocols and analytical needs
  • 7 pre-installed application programmes — ready to use immediately
  • Compact footprint — takes up minimal space in the laboratory
  • Low noise — maximum noise level ≤ 49 dB(A)
  • Low consumable costs — reliable results with low consumption of consumable materials
  • Choice of 12- or 24-place rotor — scalable to suit analysis volume
  • IVDR-certified — complies with EU Regulation (EU) 2017/746 for in vitro diagnostics
  • Brushless motor — long service life and maintenance-free operation

Technical specifications

Functions

  • Metal housing and lid with inspection window
  • Single-handed lid lock
  • Lid drop protection
  • Emergency lid release
  • Brushless motor
  • Error display on screen
  • Imbalance shutdown upon detection of imbalance
  • Colour touchscreen with real-time values for all parameters
  • Audible signal upon completion of centrifugation run
  • 24 programme memories
  • 7 pre-installed application programmes
  • Ethernet interface (connectivity)
  • Inlet for saline solution (Kochsalz solution) and drain

Rotor alternatives

Documentation

Data sheet – Hettich Rotolavit II (PDF)

TYPE DETAILS
IVDR certification In accordance with EU Regulation (EU) 2017/746 for in vitro diagnostics
Electrical safety CPS certified – C/US (electrical safety)
EMC (Europe) EN/IEC 61326-3-2, Class B
EMC (USA) FCC CFR47 part 15, Class B

Dimensions

Who is Hettich Rotolavit II suited for?

USER GROUP REASON
Transfusion centres and blood banks Primary target group — developed specifically for crossmatching and antibody testing
Immunohaematological laboratories Automates cell washing in serological analyses
Clinical laboratories with TB testing Supports cell washing in tuberculosis tests
Hospitals with high analysis volumes 24-place rotor provides efficient throughput
Laboratories with space constraints Compact design and small footprint suits confined laboratory spaces

About the Manufacturer Hettich

Andreas Hettich GmbH & Co. KG is a German manufacturer of laboratory equipment with extensive experience in developing centrifuges for research, diagnostics and industry. The company is headquartered in Tuttlingen, Germany, and supplies laboratory solutions to universities, hospitals and research institutions worldwide.

Hettich is renowned for high quality, operational reliability and precise technology, and its products are used in everything from routine analyses to advanced research projects. The product range includes laboratory centrifuges, refrigerated centrifuges and specialised solutions for analytical and development laboratories.

At Labhuset you will find a selection of centrifuges from Hettich tailored to the needs of modern laboratories.

FAQ

Frequently Asked Questions

The ROTOLAVIT II is a specialised automatic cell washing system — not a general-purpose centrifuge. It has been developed specifically for serological procedures such as crossmatching, antibody screening and cell washing in TB tests, and features built-in connectivity for saline solution supply and drainage.

The centrifuge is compatible with standard serum tubes in sizes 12 × 75 mm (5 ml) and 10 × 75 mm (3 ml). Tubes of 10 × 75 mm require adapter cat. no. 1019, supplied in packs of 12.

Yes. The centrifuge has 24 programme memory positions and 7 pre-installed application programmes. Custom protocols can be easily programmed via the intuitive colour touchscreen.

Yes. The ROTOLAVIT II is IVDR-certified in accordance with EU Regulation (EU) 2017/746 for in vitro diagnostic medical devices. Please note that the product is not available in all countries.

Both rotors operate at the same maximum speed (3,500 RPM) and RCF (1,438), however the 24-place rotor (cat. no. 1018-A) doubles the throughput compared to the 12-place rotor (cat. no. 1017-A). The choice depends on analysis volume and laboratory capacity.